International Journal of Cardiology
Volume 136, Issue 2 , Pages 171-177, 14 August 2009

Evaluation of new automated gated-SPECT and echocardiographic methods for calculating left ventricular volumes and ejection fraction

Department of Clinical Physiology, Sahlgrenska University Hospital, SE-413 45 Göteborg, Sweden

Received 30 November 2007; received in revised form 20 March 2008; accepted 23 April 2008. published online 14 August 2008.

Abstract 

Background

Left ventricular (LV) volumes and ejection fraction (LVEF) are assessed using ECG-gated myocardial perfusion scintigraphy (MPS) and echocardiography. We have developed CAFU, a new automated method for the quantification of MPS images. AutoEF software is a new automated method for quantifying echocardiograms (Tomtec research arena). The aim of the study was to compare these new methods with standard methods.

Methods

Patients undergoing clinical MPS were invited to an echocardiographic examination. Eighty-eight patients were included, mean age 64±10 years, 50% men. LV volumes and LVEF from the echocardiographic examinations were calculated using the AutoEF software and calculations according to Simpson's rule. The LV volumes and LVEF from the MPS images were calculated using CAFU, Quantitative gated-SPECT (QGS) and Emory Cardiac Toolbox (ECT).

Results

The MPS methods revealed larger LV volumes and LVEF compared with the echocardiographic methods. CAFU showed an excellent correlation with QGS and ECT (0.91–0.99). The correlations between the MPS and the echocardiographic methods (0.47–0.88), as well as between the AutoEF-assessed values and Simpson's method (0.57–0.87), were lower, however statistically significant. The correlations between the methods were higher for LV volumes than for LVEF.

Conclusion

There was better agreement between LV volumes and LVEF values from the three MPS methods than between those from the two echocardiographic methods. The echocardiographic methods produced significantly lower LV volumes and LVEF compared with the MPS methods. In the clinical situation, LV volumes and LVEF values from different types of examination or different software packages should be treated with caution.

Keywords: Myocardial perfusion scintigraphy, Echocardiography, Left ventricular volumes, Left ventricular ejection fraction, Automated method

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

 This study was supported by grants from the Göteborg Medical Society, Göteborg, and Sahlgrenska University Hospital, Göteborg, Sweden.

PII: S0167-5273(08)00620-7

doi:10.1016/j.ijcard.2008.04.082

International Journal of Cardiology
Volume 136, Issue 2 , Pages 171-177, 14 August 2009